5 changes: 3 additions & 2 deletions src/ProcessBus.App.Wpf/MainWindow.xaml
Original file line number Diff line number Diff line change
Expand Up @@ -2002,7 +2002,7 @@
<Style TargetType="Border">
<Setter Property="Visibility" Value="Collapsed"/>
<Style.Triggers>
<DataTrigger Binding="{Binding IsRunning}" Value="True">
<DataTrigger Binding="{Binding IsSelectedSvReceiving}" Value="True">
<Setter Property="Visibility" Value="Visible"/>
</DataTrigger>
</Style.Triggers>
Expand All @@ -2014,7 +2014,7 @@
<Style TargetType="Ellipse">
<Setter Property="Opacity" Value="0.55"/>
<Style.Triggers>
<DataTrigger Binding="{Binding IsRunning}" Value="True">
<DataTrigger Binding="{Binding IsSelectedSvReceiving}" Value="True">
<DataTrigger.EnterActions>
<BeginStoryboard x:Name="LiveDotPulseStoryboard">
<Storyboard AutoReverse="True" RepeatBehavior="Forever">
Expand Down Expand Up @@ -2205,6 +2205,7 @@
Command="{Binding CopyEvidenceCommand}"
ToolTip="Copy original engineering values and passive capture evidence"/>
<ComboBox Height="28" MinWidth="140"
IsEnabled="{Binding CanSelectEngineeringScale}"
Style="{StaticResource CompactComboBoxStyle}"
ItemsSource="{Binding EngineeringScaleOptions}"
SelectedItem="{Binding SelectedEngineeringScale, Mode=TwoWay, UpdateSourceTrigger=PropertyChanged}"
Expand Down
22 changes: 18 additions & 4 deletions src/ProcessBus.App.Wpf/ViewModels/MainWindowViewModel.cs
Original file line number Diff line number Diff line change
Expand Up @@ -57,7 +57,7 @@
private string? _lastPhasorSourceStreamId;
private readonly Dictionary<string, SvEngineeringScale> _explicitSvScales = new(StringComparer.OrdinalIgnoreCase);
private const string RawScaleText = "Raw counts (uncalibrated)";
private const string NominalScaleText = "4I+4V nominal (1 mA / 10 mV per count)";
private const string NominalScaleText = "4I+4V nominal";
private string _waveformShowMode = "Both";
private string _waveformLayoutMode = "Overlay";
private string _waveformTimebase = "2 cycles";
Expand Down Expand Up @@ -110,6 +110,7 @@
_isRunning = value;
OnPropertyChanged();
OnPropertyChanged(nameof(CanSwitchCaptureMode));
OnPropertyChanged(nameof(IsSelectedSvReceiving));
}
}

Expand Down Expand Up @@ -764,6 +765,8 @@
ApplySelectedStreamScale(value?.StreamId);
OnPropertyChanged(nameof(SelectedEngineeringScale));
OnPropertyChanged(nameof(EngineeringScaleExplanation));
OnPropertyChanged(nameof(CanSelectEngineeringScale));
OnPropertyChanged(nameof(IsSelectedSvReceiving));
RestoreSelectedStreamWorkspace(value);
OnPropertyChanged();
OnPropertyChanged(nameof(AnalogValues));
Expand Down Expand Up @@ -880,6 +883,11 @@
public IReadOnlyList<string> WaveformMarkerOptions { get; } = ["On", "Off"];
public IReadOnlyList<string> EngineeringScaleOptions { get; } = [NominalScaleText, RawScaleText];

// Before SV discovery this is a display preset only. No incoming samples,
// physical units or fabricated measurements are implied.
public bool CanSelectEngineeringScale => SelectedStream is not null;
public bool IsSelectedSvReceiving => IsRunning && SelectedStream is { IsActive: true };

private SvEngineeringScale ResolveSelectedStreamScale(string streamId)
{
if (_explicitSvScales.TryGetValue(streamId, out var explicitMode))
Expand All @@ -899,8 +907,9 @@

public string SelectedEngineeringScale
{
get => SelectedStream is not null &&
ResolveSelectedStreamScale(SelectedStream.StreamId) == SvEngineeringScale.Nominal4I4V
get => (SelectedStream is null
? SvEngineeringScaleFactors.IdlePresentationDefault
: ResolveSelectedStreamScale(SelectedStream.StreamId)) == SvEngineeringScale.Nominal4I4V
? NominalScaleText : RawScaleText;
set
{
Expand All @@ -925,7 +934,7 @@
}

public string EngineeringScaleExplanation => SelectedStream is null
? "Select an SV stream to see its measurement units."
? "Waiting for publisher. Nominal 4I+4V is a display preset, not a measurement; no values until recognized SV data arrives."
: SelectedEngineeringScale == NominalScaleText
? "Assumed 4I+4V nominal: 1 mA / 10 mV per count. Display estimate only; not calibrated or SCL-verified. Choose Raw counts anytime."
: "Raw SV counts: no electrical units inferred. Use nominal 4I+4V only when its layout is confirmed.";
Expand Down Expand Up @@ -2182,6 +2191,8 @@
_selectedStream = refreshed;
RestoreSelectedStreamWorkspace(refreshed);
OnPropertyChanged(nameof(SelectedStream));
OnPropertyChanged(nameof(IsSelectedSvReceiving));
OnPropertyChanged(nameof(CanSelectEngineeringScale));
OnPropertyChanged(nameof(AnalogValues));
OnPropertyChanged(nameof(Phasors));
OnPropertyChanged(nameof(Waveform));
Expand Down Expand Up @@ -2218,6 +2229,8 @@
OnPropertyChanged(nameof(SelectedStream));
OnPropertyChanged(nameof(SelectedEngineeringScale));
OnPropertyChanged(nameof(EngineeringScaleExplanation));
OnPropertyChanged(nameof(CanSelectEngineeringScale));
OnPropertyChanged(nameof(IsSelectedSvReceiving));
}

private void RestoreSelectedStreamWorkspace(SvStreamItem? stream)
Expand Down Expand Up @@ -2546,6 +2559,7 @@
{
_lastGlobalRaiseUtc = now;
OnPropertyChanged(nameof(StreamStatusText));
OnPropertyChanged(nameof(IsSelectedSvReceiving));
OnPropertyChanged(nameof(OperatorCaptureSummaryText));
OnPropertyChanged(nameof(DataSourceName));
OnPropertyChanged(nameof(IsLiveMode));
Expand Down Expand Up @@ -4586,7 +4600,7 @@
public double? DeltaMs { get; init; }
public string SemanticChangedSummaryText { get; init; } = string.Empty;

public string TimeText => Source.LastSeenUtc.ToString("HH:mm:ss.fff");

Check warning on line 4603 in src/ProcessBus.App.Wpf/ViewModels/MainWindowViewModel.cs

View workflow job for this annotation

GitHub Actions / Build verified Windows x64 candidate

The behavior of 'DateTime.ToString(string)' could vary based on the current user's locale settings. Replace this call in 'GooseTrafficRow.TimeText.get' with a call to 'DateTime.ToString(string, IFormatProvider)'. (https://learn.microsoft.com/dotnet/fundamentals/code-analysis/quality-rules/ca1305)
public string DeltaText => DeltaMs.HasValue ? $"{DeltaMs.Value:0.0}" : "-";

public string GoId => Source.GoId;
Expand Down Expand Up @@ -4631,11 +4645,11 @@
}
}
public string AppId => Source.AppId;
public string EntryTimeText => Source.LastSeenUtc.ToLocalTime().ToString("M/d/yyyy h:mm:ss.fff tt");

Check warning on line 4648 in src/ProcessBus.App.Wpf/ViewModels/MainWindowViewModel.cs

View workflow job for this annotation

GitHub Actions / Build verified Windows x64 candidate

The behavior of 'DateTime.ToString(string)' could vary based on the current user's locale settings. Replace this call in 'GooseTrafficRow.EntryTimeText.get' with a call to 'DateTime.ToString(string, IFormatProvider)'. (https://learn.microsoft.com/dotnet/fundamentals/code-analysis/quality-rules/ca1305)
public string NeedsCommissionText => Source.NeedsCommission ? "true" : "false";
public string TestText => Source.IsTest ? "true" : "false";
public int DatasetEntryCount => Source.DataValues.Count;
public string DatasetEntryCountText => DatasetEntryCount.ToString();

Check warning on line 4652 in src/ProcessBus.App.Wpf/ViewModels/MainWindowViewModel.cs

View workflow job for this annotation

GitHub Actions / Build verified Windows x64 candidate

The behavior of 'int.ToString()' could vary based on the current user's locale settings. Replace this call in 'GooseTrafficRow.DatasetEntryCountText.get' with a call to 'int.ToString(IFormatProvider)'. (https://learn.microsoft.com/dotnet/fundamentals/code-analysis/quality-rules/ca1305)
public string DestinationMac => Source.DestinationMac;
public string SourceMac => Source.SourceMac;
public string VlanId => Source.VlanId;
Expand Down Expand Up @@ -4771,7 +4785,7 @@
var age = DateTime.UtcNow - LastSeenUtc.Value;
return age.TotalSeconds < 60
? $"last {age.TotalSeconds:0.0}s"
: LastSeenUtc.Value.ToLocalTime().ToString("HH:mm:ss");

Check warning on line 4788 in src/ProcessBus.App.Wpf/ViewModels/MainWindowViewModel.cs

View workflow job for this annotation

GitHub Actions / Build verified Windows x64 candidate

The behavior of 'DateTime.ToString(string)' could vary based on the current user's locale settings. Replace this call in 'TrafficHealthTargetRow.LastSeenText.get' with a call to 'DateTime.ToString(string, IFormatProvider)'. (https://learn.microsoft.com/dotnet/fundamentals/code-analysis/quality-rules/ca1305)
}
}

Expand Down Expand Up @@ -4852,7 +4866,7 @@
public string EntryCountText => $"{Entries.Count} entry(s)";
public string SummaryText => $"{IedName} - {TransportText}";
public string ExpectedKey => $"{Protocol}|{SourceFileName}|{IedName}|{ControlBlockReference}|{DisplayName}";
public string ExpectedConfRevText => ConfRev > 0 ? ConfRev.ToString() : "N/A";

Check warning on line 4869 in src/ProcessBus.App.Wpf/ViewModels/MainWindowViewModel.cs

View workflow job for this annotation

GitHub Actions / Build verified Windows x64 candidate

The behavior of 'int.ToString()' could vary based on the current user's locale settings. Replace this call in 'SclStreamCatalogRow.ExpectedConfRevText.get' with a call to 'int.ToString(IFormatProvider)'. (https://learn.microsoft.com/dotnet/fundamentals/code-analysis/quality-rules/ca1305)

public static SclStreamCatalogRow FromSv(string sourceFileName, SclSvStreamModel stream, string liveStatus)
=> new()
Expand Down Expand Up @@ -5081,7 +5095,7 @@
return ("No evidence captured yet", string.Empty);

var parts = evidence
.Split(new[] { "; " }, StringSplitOptions.RemoveEmptyEntries)

Check warning on line 5098 in src/ProcessBus.App.Wpf/ViewModels/MainWindowViewModel.cs

View workflow job for this annotation

GitHub Actions / Build verified Windows x64 candidate

Prefer 'static readonly' fields over constant array arguments if the called method is called repeatedly and is not mutating the passed array (https://learn.microsoft.com/dotnet/fundamentals/code-analysis/quality-rules/ca1861)
.Select(part => part.Trim())
.Where(part => part.Length > 0)
.ToArray();
Expand Down
5 changes: 5 additions & 0 deletions src/ProcessBus.Core/Models/SvEngineeringScale.cs
Original file line number Diff line number Diff line change
Expand Up @@ -12,6 +12,11 @@ public enum SvEngineeringScale

public static class SvEngineeringScaleFactors
{
// UI preset shown before any publisher is detected. It is not applied to
// an unknown stream until its decoded profile is verified or the operator
// explicitly selects nominal. No electrical values exist during idle.
public const SvEngineeringScale IdlePresentationDefault = SvEngineeringScale.Nominal4I4V;

// This explicitly opted-in 4I+4V lab/nominal profile is 1 mA per
// current count and 10 mV per voltage count. It is NOT universal
// IEC 61850 SV scaling and must never be auto-selected by svID.
Expand Down
10 changes: 10 additions & 0 deletions tests/ProcessBus.Tests/SvNominalProfilePolicyTests.cs
Original file line number Diff line number Diff line change
Expand Up @@ -5,6 +5,16 @@ namespace ProcessBus.Tests;

public sealed class SvNominalProfilePolicyTests
{
[Fact]
public void IdleUiPresetIsNominalButCannotInventMeasurementEvidence()
{
Assert.Equal(SvEngineeringScale.Nominal4I4V, SvEngineeringScaleFactors.IdlePresentationDefault);
var noSamples = new AnalogValuesSnapshot();
Assert.Null(noSamples.Ua.RmsValue);
Assert.Null(noSamples.Ia.RmsValue);
Assert.Null(noSamples.Ic.AngleDegrees);
}

[Theory]
[InlineData("Raw 4I4V instMag/q candidate profile", true)]
[InlineData("OMICRON raw 4I4V instMag/q profile / OMICRON_CMC_SV1", true)]
Expand Down
Loading